A fireplace generates heat.
Direct vent gas fireplace code requirements.
National standard building code masonry built fireplaces.
Sometimes metal shields must be used over the top of the vent to divert the heat.
The exhaust vent terminal shall be located at least 3 feet above any forced air inlet located within 10 feet.
Also see more citations at references at the end of this page.
Clearances from the fireplace box to surrounding walls and to the wood framing.
That s great for warmth but you must make sure the materials surrounding your fireplace are not flammable.
Appropriate hearth materials are tile stone brick or concrete.
36 above forced air intakes.
Gas log fireplace manuals.
In addition if the side panels of your mantel project more than 1 1 2 inches from the fireplace facing you will need additional clearance equal to this.
Side clearance to combustibles.
On the sides and back and 3 1 2 in.
Highlights of gas heater vent clearance distances.
All combustible mantel surrounds and shelves must be kept at least 12 inches from the opening of your fireplace top and sides.
The vent terminal shall be at least 12 inches below 12 inches.
Well making sure that you choose the right venting style will protect them.
The different types of venting.
The fireplace throat or damper shall be located not less than 8 inches 203 mm above the lintel.
Gas fireplace hearths may not be made of any combustible material.
5 tjernlund gas side wall power venters tjernlund corporation 1601 9th street white bear lake mn 55110 6794 tel.
Sources of direct vent gas fireplace clearance information.
Appendix c exit terminals of mechanical draft and direct vent venting systems.
R1001 7 lintel and throat masonry over a fireplace opening shall be supported by a lintel of noncombustible material.
Standard for chimneys fireplaces vents and solid fuel burning appliances nfpa 211 reduces fire hazards by ensuring the safe removal of flue gases the proper installation of solid fuel burning appliances and the correct construction and installation of chimneys fireplaces and venting systems.
When we are talking about gas furnace vent pipe code we need to talk about the different types of the vents first after all you want to keep your family safe from harm.
12 away from gravity fed air intakes.
Requirements for a gas fireplace hearth.
Floor distance to combustibles.
It consists of a figure and notes that visually depict code requirements from chapter 5 for vent terminals with respect to the openings found in building exterior walls.
Distance the vent must be kept from insulation wood and other combustibles.
The minimum required bearing length on each end of the fireplace opening shall be 4 inches 102 mm.