Duct leakage test form nc.
A duct leakage test duct testing can be performed at rough in before drywalling or post construction.
Example blank form duct leakage test form customer information.
The duct leakage information including duct leakage test selected and result tester name date and contact information shall be included on the certificate described in section n1101 3.
Duct tightness shall be verified as follows.
The system will need to achieve a leakage rate of less than 4 cfm cubic feet per minute per 100 square feet of the home.
Building air leakage visually inspected according to 402 4 2 1 or building air leakage test results sec.
Meeting the nc 2012 energy code requirements.
25 pa across the entire system including the manufacturer s air handler enclosure.
403 2 2 cfm25 total 100sf target.
Perform the hvac system air leakage test and record the cfm25.
Insulation r total duct leakage test result sect.
Total duct leakage rate must be 6 or less and recorded on the energy efficiency certificate.
Retrotec model 200 ductester operation manual for residential applications rev 2015 01 22.
For the test criteria the report shall be produced in the following manner.
Use only approved durable materials to seal ducts.
Duct air leakage test section 403 2 2 sample worksheet n1103 2 2 sealing.
All ducts air handlers filter boxes and building cavities used as ducts shall be sealed.
0 30 name of tester company.
Joints and seams shall comply with section 603 of the nc mechanical code.
Get and sign nc duct leakage test form pressure differential of 0 1 inches w g.
Mastic works best on metal ducts and seams.
If different from above street.
Ul181 labeled tape or mastic.